Short Description
- High Flow Capacity Filter Cartridges
for Depth Filtration
-
Absolute (β 5000) or Nominal Performance
- Graded Density Structure for High Dirt Holding Capacity and Long
Service Life
- Excellent Flow Characteristics
- All Polypropylene or All Nylon Construction
- Free from Adhesives, Binders and Resins
- Coreless Rigid Filter Structure
- Double Open Ended Elements
- Fast Loading and Unloading
- Advanced, Microprocessor Controlled
Melt Blown Production Process
- Lot Number Printed on Individual Cartridge Label
Specification
Filtration Efficiency *
- Absolute Rated Filter Cartridges: Minimum 99.98%
- Nominal Rated Filter Cartridges: Minimum 95%
Filter Fineness
Materials of Construction
- All Polypropylene or All Nylon (Coreless Filter Cartridges)
FDA Materials
- All materials of polypropylene filter cartridges meet FDA
requirements.
Standard Dimensions
- Inside Diameter: 4.49” (114 mm)
- Outside Diameter: 5.98” (152 mm)
- Length: 40” (1016 mm)
Operating Conditions
- Maximum Temperature: 80 ºC (Polypropylene Cartridges) or 150
ºC (Nylon Cartridges)
- Maximum Differential Pressure: 2 Bar at 20 ºC
- Recommended Filter Change Differential Pressure: 2 Bar
Sterilization
Particle Retention Ratings *
Example of Graph for hA0P40-10 **

Graphs of other cartridges are available on request.
Flows
Flow Rates vs Pressure Drop for Nominal Rated Cartridges
Liquid: Water Length of Cartridges: 40” Temperature: 20 ºC
Quality
Production
- Computer Controlled Melt Blown Manufacturing Process
- Programmable and Fully Repeatable Structure of the Product
- Production in Controlled Environment
- Manufacture According to Rules of ISO 9001 Quality System
- Recycling of All Waste Products
Quality Control
- Samples from all lots are tested using a single pass, modified
test.
- Lot number is printed on individual cartridge label.
Product Marking
- Product code, lot number and production date are printed on
individual cartridge label.
Ordering Guide
____________
* Test results are collected using a single pass, modified,
destructive test with A3 BSW laser particle counter. As the test
contaminant ISO Fine Test Dust 12103-1, A2 and ISO Coarse Test Dust
12103-1, A4 are used for filter ranges up to 20 µm and over 20 µm
respectively.
** See: Ordering Guide
|